-
0,26 € netto
Rectifier for the Flatpack 2 power supply(48 V, 2000 W) with high power and reliability. The device is versatile, so it can be used for various types of applications. Plug and Play connection facilitates assembly and installation, removing the need for additional equipment. The rectifier is equipped with digital control that allows convenient monitoring and adjustment.
Examples of applications include wireless, fixed-line telephony and SCADA systems.
The most important features:
- digital control - the number of components has been reduced by 40%, which has increased the reliability and extended service life of DC power systems:
- cooling - forward and backward air flow with an integrated heat sink ensure good working conditions;
- protection of the output with the OR-ING diode;
- global approvals - the device meets the requirements of CE, UL and is NEBS certified.
Specification:
Prostownik Flatpack2 48/2000 | |
Input parameters | |
---|---|
Voltage range (nominal) | 185 - 275 VAC |
Voltage range (maximum) | 85 - 300 VAC |
Frequency | 44 - 66 Hz |
Maximum current, at nominal input and at full load | 12,5 A rms |
Power factor | > 0,99 above 50% load |
Protections |
Fuse on the power supply of both lines overvoltage protection disconnection above 290 VAC |
Output parameters | |
Nominal voltage | 53,5 VDC |
Voltage range | 43,5 - 57,6 VDC |
Maximum power | 2000 W |
Maximum power at 85 VAC | 850 W |
Maximum current, at nominal input and at full load | 41,7 A (at 48 VDC) |
Current split (load 10% - 100%) | ± 5% of the maximum current for loads from 10% to 100% |
Static voltage regulation (load 10% - 100%) | ±0,5% |
Dynamic voltage regulation | ± 5.0% for 10-90% or 90-10% load changes, control time <50ms |
Backup time at 1500 W output power | > 20 ms, output voltage> 43.5 VDC |
Noise and loudness | <100 mV ptp, 30 Hz bandwidth, <0.96 mV rms psophometric |
Protections |
OR-ING diode short circuit protection high temperature protection overvoltage disconnection |
Others | |
Efficiency at nominal voltage | up to 92,5% |
Insulation |
3, 0 kV AC - input and output 1.5 kV AC - input and ground 500 V DC - output and ground |
Alarm: red LED | Shutdown: low and high voltage, low and high temperature, high output voltage. Damage to: rectifier, fan, CAN bus. Low output voltage alarm at 43.5Vdc. |
Warning: yellow LED | Rectifier in power limitation, flicker on overvoltage cut-off, loss of communication with CAN bus |
Green LED | Normal operation, no problems. |
Cooling | Active, One fan (front to back air flow, load and temperature adjustable) |
Noise | <55 dBA at nominal voltage and maximum load (ambient T <30 ° C) |
MTBF (Telcordia SR-332 1st edition method III (a)) | > 350000 (T ambient: 25 °C) |
Working temperature |
-40 to 75 ° C humidity: 5% - 95% RH non-condensing |
Storage temperature |
-40 to 85 ° C humidity: 0% - 99% RH non-condensing |
Dimensions / weight | 109x41,5x327 mm / 1,9 kg |
Standards | |
Electrical safety |
UL 60950-1:2007, IEC 60950-1:2005+A1:2009 EN 60950-1:2006+A11:2009+A1:2010+A12:2011 |
EMC |
EN 61000-6-1:2007, -6-2:2005, -6-3:2007 +A1:2011, -6-4:2007 +A1:2011 ETSI EN 300 386 V.1.6.1, Telcordia NEBS GR1089 CORE |
Environmental |
ETSI EN 300 019: 2-1 (klasa 1,2), 2-2 (klasa 2,3) i 2-3 (klasa 3,2) ETSI EN 300 132-2, Telcordia NEBS GR63 CORE Zone 4 Compliant with RoHS (2011/65 / EU) and WEEE (2002/96 / EC) |