1,10 zł netto
The sinusPRO-1000E device combines the functionality of a DC / AC (12 V) inverter, a backup power supply (UPS), a voltage regulator and a battery charger. The rated power is 1000 VA, and the maximum charging current is 10 A. The product uses a toroidal transformer ensuring higher efficiency and energy efficiency than structures based on transformers with E cores. The inverter quickly switches from mains power to UPS, thanks to which the connected equipment can work smoothly. An additional advantage is the LCD display informing about the current operating status.
The inverter generates an alternating voltage with a sinusoidal waveform, identical to that in the power grid. Thanks to this, it is possible to power devices equipped with electric motors and transformers, such as electric tools, pumps and low-power household appliances. There is no risk of damaging the powered equipment, which occurs when using inverters with a square wave voltage.
The most important features:
- DC / AC inverter (12 V);
- UPS uninterruptible power supply;
- voltage regulator and battery charger;
- rated power 1000 VA;
- charging current 10 A;
- sine wave output voltage
Specification
sinusPRO-1000E | |
Rated power | 1000 VA |
Battery voltage | 12 V DC |
Maximum charging current | 10 A |
Charging voltage | 13,8 V (± 0,5 V) |
Admissible range of supply voltage | Switching to battery operation takes place when the mains voltage is lower than 160 V (± 5 V) or higher than 260 V (± 5 V) |
Supply voltage frequency | 45 Hz - 65 Hz |
Output voltage range |
Mains voltage regulator: 204 - 240 V UPS uninterruptible power supply: 230V (± 3%) |
The frequency of the UPS output voltage | 50 Hz (± 0,5 Hz) |
Overload protection |
Battery operation mode: in case of 110% - 130% overload, the power is disconnected after 30 seconds. If the overload is greater than 130%, the power is disconnected immediately. In the mains supply mode, the device warns of overloading until the fuses are blown. |
Permissible operating temperature | From 0 to 40 °C |