The UPDS40 is a 40A DIN rail type DC-UPS module, and it is paired with a power supply and an external battery to achieve the backup function. When the AC mains fails or is interrupted, the load will be immediately connected to the battery pack to avoid interruption and to ensure the continous operation of the entire system (the operating time depends on the capacity of the battery pack).
The main features of DUPS40 include: fast installation, suitability for 24V battery pack and various capacities of 4Ah ~ 135Ah, 2A battery charging current, low voltage disconnect for battery protection and more. The product is suitable for use in data centers, security systems, emergency lightning, wireless communication UPS, central monitoring systems etc.
Specifications
DUPS40 | |
DC UPS input | |
---|---|
Normal input voltage | 24 V DC |
Input voltage range | 24 - 29 V DC |
Rated current | 40 A |
DC UPS output | |
Voltage range | 21 - 29 V DC |
Discharge current range | 0 - 40 A |
Charging current | 2 A |
Battery | |
Normal battery voltage |
24Vdc ( 2 x 12Vdc in series or 1 x 24Vdc) |
Battery type | Lead-acid battery |
External battery capacities | 4 - 135 Ah |
Protection | |
Battery polarity |
Protected by internal detection, No Damage, recovers automatically after fault conduction is removed |
Short circuit |
This protection only works when batteries are not connected, No Damage. External fuse is recommended when batteries are connected. |
Over discharge current | 42~46A,After 3 sec., unit will cut-off battery discharging by relay |
Battery deep discharge | Cut-off battery discharging by relay |
Function | |
Relay contact ragings (max) |
30VDC/1A resistive load |
DC BUS OK |
Relay contact : Short when DC voltage between 21~29V(±2%), relay contacts LED(Green) : DC BUS OK : light ; DC BUS fail : dark |
BATTERY FAIL |
Short when battery voltage falls below 22V(±2%) or battery failure is observed through the battery test function, relay contacts LED(Red) : Battery over-discharge warning or battery broken : light ; Battery OK : dark |
BATTERY DISCHARGE |
Relay contact : Short when battery in discharge condition, relay contacts LED(Yellow) : light : Battery discharging ; dark : Battery is not discharging or discharging current < 2.0A |
Environment | |
Cooling | Free air convection |
Working temperature | -30 ~ +70℃ (Refer to "Derating Curve") |
Working humidity | 5 ~ 95% RH non-condensing |
Others | |
MTBF | 1376.5K hrs min. Telcordia SR-332 (Bellcore) ; 499.5K hrs min. MIL-HDBK-217F (25℃) |
Dimensions | 63 x 125.2 x 113.5mm (W*H*D) |