0,25 € netto
LRS-150-48 is the power supply of the popular company Mean Well. It has a modular housing, it should be built into the mounting box. The input voltage is 85 - 132 V AC or 170 - 264 V AC, the voltage range is changed by means of a switch on the housing. The output voltage is 48 V DC, and current 3.3 A,which gives us about 158 W of power. The power supply is distinguished by its high efficiency of 90% and its low power consumption, which does not exceed 0.7 W.
The offered product is ideally suited to power devices with high power consumption or several standard telecommunications devices. It is an efficient and reliable solution. The power supply has all necessary protections: overload, overvoltage and overheat.
- input voltage 85 - 132 V AC / 170 - 264 V AC;
- output voltage 43,2 - 52,8 V DC;
- output current: 3,3 A;
- power: about 158 W;
- efficiency 90%.
Specification
LRS-150-48 | |
Output | |
---|---|
Voltage | 48 V DC |
Current | 3,3 A |
Current range | 0 - 3,3 A |
Power | About 158,4 W |
Noise and noise | 200 mVp-p |
Voltage range | 43,2 - 52,8 V DC |
Voltage tolerance | ± 1% |
Stabilization from changes electricity | ± 0,5% |
Stability from load changes | ± 0,5% |
Set time / rise time, holding time |
500 ms / 30 ms / 40 ms at 230 V AC 500 ms / 30 ms / 35 ms at 115 V AC |
Input | |
Voltage |
85 - 132 V AC / 170 - 264 V AC (to be selected by a switch in the housing) |
Frequency range | 47 - 63 Hz |
Efficiency | 90% |
Current |
3 A at 115 V AC 1,7 A at 230 V AC |
Inrush current | 60 A przy 230 V AC |
Leakage Current | < 0,75 mA / 240 V AC |
Protection | |
Overload | It will operate at 110 - 140% of output power |
Overvoltage | 55,2 - 64,8 V DC output voltage |
Overheat | In the event of overheating, the device turns off |
Other features | |
Permissible working temperature | Od -30 do 70°C |
Permissible storage temperature | Od -40 do 85°C |
Permissible humidity during operation | 20%-90% RH non-condensing |
Permissible air humidity during storage | 10%-95% RH non-condensing |
Certificates |
UL60950-1 TUV EN60950-1 EN60335-1 EN61558-1/-2-15 CCC GB4943 EN55032 (CISPR32) GB9245 Class B EN55014 EN61000-3-2 Class A EN61000-3.3 EN6100-4-2, 3, 4, 5, 6, 8, 11 EN6100-6-2 (EN50082-2) |
MTBF |
Min. 601K hours MIL-HDBK-217F (25°C) |
Dimensions | 159x97x30 mm |