-
0,26 $ netto
The AD-155A power supply is designed to be built inside the powered device. It is characterized by small size and high efficiency. The device is equipped with a battery disconnector (RGR) system, which protects the battery against overdischarge.
The use of AD-155A is: powering electronic devices, industrial automation, access control systems, alarm systems, etc. in cooperation with a battery of maintenance-free batteries.
The most important features:
- universal AC supply voltage / Full range;
- PF>0,92@230V;
- protection: short circuit, overvoltage and overload protection;
- protection against voltage drop and battery reverse polarity;
- pulse working frequency 134kHz;
- passive cooling,
- possible mounting on a DIN rail or mounting plate.
- 2 years warranty.
Specification
AD-155A | ||
Output | ||
---|---|---|
Output number | CH1 | CH2 (battery) |
Voltage | 13,8 V | 13,4 V |
Current | 10,5 A | 0,5 A |
Current range | 0 - 11,5 A | 0 - 0,5 A |
Power | 151,55 W | |
Ripple & noise | 150m Vp-p | |
Output voltage adjustment | 12 - 14,5 V | |
Output voltage tolerance | ± 2% | |
Stabilization from the electrical grid | ± 0,5% | |
Stabilization from load changes | ± 0,5% | |
Set / rise / hold time |
1000 ms / 90 ms / 20 ms on power 230 V AC 2000 ms / 90 ms / 16 ms on power 115 V AC |
|
Input | ||
Input voltage range |
88 - 264 V AC 124 - 370 V DC |
|
Frequency range | 47 - 63 Hz | |
Efficiency | 80% | |
Input current |
2,5 A / 115 V AC 1,5 A / 230 V AC |
|
Maximum current shock |
Inrush current 20 A / 115 V AC; 40 A / 230 V AC |
|
Leakage current | < 1 mA / 240 V AC | |
Protection | ||
against overload |
105 - 135% of maximum output power. Type of protection: cut-off of the output voltage, voltage recovery occurs when the CH2 overload (battery) is removed: 0.51 - 0.9 A. |
|
against overvoltage | CH1: 14,49 - 18,63 V | |
against overdischarge |
10 V ±0,8 V |
|
Environment | ||
Working temperature | From -10 to 60 °C | |
Permissible humidity | 20%-90% non-condensing | |
Storage temperature and humidity |
from -20 to 85 °C 10%-95% RH |
|
Temperature dependent efficiency | ± 0,03% / °C (0 - 50 °C) on output CH1 | |
Vibes | 10 - 500 Hz, 2G 10 min / 1 cycle, 60 min along each axis X, Y, Z | |
Safety | ||
Standards |
UL60950-1 TUV EN60950-1 |
|
Insulation test voltages |
I/P-O/P: 3k V AC I/P-FG: 1,5k V AC O/P-FG: 0,5k V AC |
|
Insulation resistance | I/P-O/P, I/P-FG, O/P-FG: 100M ohm / 500 V DC | |
EMI emitted and conducted | Compliant with the standard EN55022 (CISPR22) B class | |
Harmonics | Compliant with the standard EN61000-3-2,3 | |
EMS immunity |
Compliant with the standard EN61000-4-2,3,4,5,6,8,11 ENV50204 EN55024 |
|
Others | ||
MTBF | 183.3 thousand hours according to the MIL-HDBK-217F (25 ° C) standard | |
Dimensions | 159x97x38 mm | |
Weight | 0,88 kg |